Quiz: A320: Pneumatics & Air Conditioning

Test your knowledge of the Airbus A320's Pneumatics & Air Conditioning systems.

While I have tried to ensure the information in this quiz is accurate, it is your own responsibility to check it against your airline / manufacturer manuals. With that said, if you spot any obvious errors then please let me know the question number and I'll aim to put it right!

Q14362 What is the typical Bleed Air Pressure?

Correct!

Incorrect!

Q14368 When does the bleed air temperature / pressures box turn amber on the SD?

Correct!

Incorrect!

Q14369 Is WAI (Wing Anti Ice) allowed if only one bleed system is in operation?

Correct!

Incorrect!

Q14359 On the SD, when/how is GND displayed?

Correct!

Incorrect!

Q14373 What controls the Packs and Trim Air Values?

Correct!

Incorrect!

Q14365 With the XBLEED switch in AUTO, what determines XBLEED value position?

Correct!

Incorrect!

Q14384 [RAM AIR] What is the outflow value position at or greater than 1 PSI of differential pressure?

Correct!

Incorrect!

Q14371 What should you NOT do if HP Air Starter is connected to the pneumatics system?

Correct!

Incorrect!

Q14356 What happens if BMC fails?

Correct!

Incorrect!

Q14363 How is Bleed Air Temperature regulated?

Correct!

Incorrect!

Q14378 The Zone Temperature Controllers can be Set to what Range of temps?

Correct!

Incorrect!

Q14360 During Normal operation, when would the HP value open?

Correct!

Incorrect!

Q14355 How many BMCs are there?

Correct!

Incorrect!

Q14370 What should you NOT do if GD LP Air is connected to the pneumatics system?

Correct!

Incorrect!

Q14358 If a BMC fails, what happens to the bleed values?

Correct!

Incorrect!

Q14379 What happens if an ACSC has a LANE failure?

Correct!

Incorrect!

Q14382 What happens when the Ram Air Pushbutton is selected ON?

Correct!

Incorrect!

Q14385 [RAM AIR] What is the outflow value position less than 1 PSI of differential pressure?

Correct!

Incorrect!

Q14377 What conditions could cause the Pack Flow to be Higher than that Selected on the Overhead Panel?

Correct!

Incorrect!

Q14381 When does a Pack Overheat FAULT light, (on OHP) extinguish?

Correct!

Incorrect!

Q14367 In normal operation which bleed air source has priority?

Correct!

Incorrect!

Q14383 What Limitation(s) apply to the Opening of the Ram Air Valve?

Correct!

Incorrect!

Q14366 What happens if a leak is detected when the XBLEED switch is in the AUTO position?

Correct!

Incorrect!

Q14380 What happens if an ACSC has a Double LANE failure?

Correct!

Incorrect!

Q14376 When does the Ram Air Inlet Flap close?

Correct!

Incorrect!

Q14374 What happens to the air conditioning system during Engine Start?

Correct!

Incorrect!

Q14375 What happens when a Duct Overheat occurs in the wings?

Correct!

Incorrect!

Q14372 How are cabin zone temperatures individual controlled?

Correct!

Incorrect!

Q14364 What temperature is bleed air regulated to within the pre-cooler?

Correct!

Incorrect!

Q14361 How is Bleed Air Pressure regulated?

Correct!

Incorrect!

Q14357 What is lost with the failure of BMC1?

Correct!

Incorrect!